High-Capacity Precision Balances

Specifications

ModelGX-8202M / GF-8202MGX-8202MD / GF-8202MDGX-10202M / GF-10202MGX-12001M / GF-12001MGX-22001M / GF-22001MGX-32001M / GF-32001MGX-32001MD / GF-32001MD
Capacity8.2 kg2.2 kg / 8.2 kg * 10.2 kg12.2 kg22.2 kg32.2 kg6.2 kg / 32.2 kg *
Readability0.01 g0.01 g / 0.1 g * 0.01 g0.1 g0.1 g / 1 g *
Repeatability(standard deviation)0.01 g0.01 g / 0.05 g0.01 g0.1 g0.1 g / 0.5 g
Linearity±0.03 g±0.02 g / ±0.1 g±0.03 g±0.2 g±0.2 g / ±1 g
Stabilization time(typical when set to FAST)Approx. 1.5 seconds
Counting mode Minimum unit mass0.01 g0.1 g0.01 g0.1 g1 g
Number of samples10, 25, 50 or 100 pieces
Percent mode Minimum 100 % reference mass1 g10 g1 g10 g100 g
% readability0.01 %, 0.1 % or 1 % (depends on the reference mass stored)
Weighing pan size270 mm × 210 mm
External dimensions300(W) × 355(D) × 111(H) mm
Net weightGX-M: Approx. 9.3 kg / GF-M: Approx. 8.3 kg

Features

  • IP65 dust and waterproof
  • Impact shock detection(ISD) providing feedback to prevent damage to the weight sensor * 1
  • Flow rate display(FRD) that makes calculating and recording flow rates easier and more accurate * 2
  • Shock logging function that records up to 50 adverse impact loads with a timestamp for later inspection
  • Cushioning under the weighing pan to mitigate impact shocks significantly
  • Flow rate comparator that indicates whether the flow rate is within the designated limits
  • Tare memory function that saves the tare value in non-volatile memory
  • Automatic self calibration in response to temperature changes or according to set schedules(GX-M)
  • Automatic minimum weight calculation with either ECL or an actual, external weight
  • Alert function to ensure that the measured quantity is not smaller than the set minimum weight
  • Selectable response characteristics for trading weighing speed for higher display stability or vice versa
  • User access control(UAC) that password-protects the balance from misuse
  • GLP / GMP / GCP / ISO compliant output to meet documentation requirements
  • Universal Flexi Coms(UFC) to customize printout content and layout * 3
  • Gross / Net / Tare output
  • Data memory function to save weighing results, calibration results, unit masses to be used in counting mode, etc., in the device itself
  • Counting mode with the Automatic Counting Accuracy Improvement(ACAI) function
  • Percent mode function for target weighing or checking sample variation
  • Animal weighing(average & hold) function for weighing moving objects
  • Statistical calculation function (SCF) to facilitate the analysis of measurements
  • Five-level comparator function with buzzer
  • Auto power ON and OFF functions
  • Density determination function